Research Hub โ€” SeraNova

Reusable Pen Guide

Step-by-step setup and usage instructions for your SeraNova reusable pen system. Select your pen type below to get started.

๐Ÿ–Š๏ธ
V1 Premium Pen
SeraNova's dedicated reusable injection pen โ€” designed for the SeraNova cartridge system
โš™๏ธ
Classic Pen (Novopen 4)
Convert your Novopen 4 using the included orange adapter conversion kit
๐Ÿ–Š๏ธ

V1 Premium Reusable Pen

The SeraNova V1 pen is a dedicated reusable injection pen designed specifically for use with SeraNova prefilled cartridges. Simple to set up, elegant to use, and built for long-term consistency.

๐Ÿ“ฆ What's Included
๐Ÿ–Š๏ธ
V1 Reusable Pen Body
๐Ÿ’‰
SeraNova Prefilled Cartridge
๐Ÿชก
8 Premium Pen Needles
๐Ÿงน
Alcohol Swabs
Setup Instructions
1
๐Ÿ–Š๏ธ
Image: Remove pen cap
Step 1

Remove the Pen Cap

Pull the cap off the pen body to expose the cartridge holder end.

2
๐Ÿ”ฉ
Image: Unscrew cartridge holder
Step 2

Unscrew the Cartridge Holder

Twist the cartridge holder anticlockwise and separate it from the pen body.

3
๐Ÿ’‰
Image: Insert cartridge into holder
Step 3

Insert the SeraNova Cartridge

Place your SeraNova prefilled cartridge into the cartridge holder with the rubber stopper end facing the pen body.

4
๐Ÿ”ง
Image: Reattach holder to pen body
Step 4

Reattach the Holder to the Pen Body

Screw the cartridge holder back onto the pen body clockwise until firmly attached. Wipe the cartridge stopper with an alcohol swab.

5
๐Ÿชก
Image: Attach pen needle
Step 5

Attach a Fresh Pen Needle

Take a new pen needle, remove the paper tab, and screw it onto the cartridge holder end clockwise until secure.

6
โœ…
Image: Prime and confirm flow
Step 6

Prime the Pen

Remove both needle shields. Dial to 2 units and press the injection button to prime โ€” a small drop at the needle tip confirms correct flow.

7
๐Ÿ”ข
Image: Dial target dose
Step 7

Dial Your Target Dose

Turn the dose dial to your target unit number as calculated by the SeraNova Dosage Calculator.

8
๐Ÿ’Š
Image: Perform injection
Step 8

Perform the Injection

Wipe the injection site with an alcohol swab. Insert the needle subcutaneously and press the button fully. Hold for 10 seconds before removing.

๐Ÿชก After Each Injection โ€” Needle Disposal
1

Replace the outer needle shield and unscrew the needle anticlockwise to remove it safely.

2

Dispose of the used needle safely. Never reuse a pen needle between injections.

3

Replace the pen cap and store the pen refrigerated between 2โ€“8ยฐC until next use.

โš™๏ธ

Classic Pen โ€” Novopen 4 Conversion

The Classic Pen system uses a Novopen 4 pen body converted using the included orange adapter kit. The two-piece orange conversion kit allows the SeraNova cartridge to be used with the Novopen 4 pen body.

๐Ÿ”ถ

Orange Conversion Kit Included

Your Classic Pen system includes two orange adapter pieces โ€” a spacer that fits around the plunger and a screw adapter that attaches to the cartridge. Both are required for conversion.

๐Ÿ“ฆ What's Included
โš™๏ธ
Novopen 4 Pen Body
๐Ÿ”ถ
Orange Spacer (Plunger)
๐Ÿ”ถ
Orange Screw Adapter (Cartridge)
๐Ÿ’‰
SeraNova Prefilled Cartridge
Conversion & Setup Instructions
1
๐Ÿ”ฉ
Image: Unscrew pen body from cartridge holder
Step 1

Unscrew the Pen Body

Twist the Novopen 4 pen body anticlockwise to unscrew and separate the pen body from the cartridge holder section.

2
๐Ÿ”ถ
Image: Slide orange spacer around plunger
Step 2

Insert the Orange Spacer

Slide the orange spacer piece around the plunger rod at the bottom of the pen body. This ensures correct plunger alignment with the SeraNova cartridge.

3
๐Ÿ”ถ
Image: Attach orange screw adapter to cartridge
Step 3

Attach the Screw Adapter to the Cartridge

Take the orange screw adapter and thread it onto the SeraNova prefilled cartridge. Screw clockwise until firmly seated on the cartridge.

4
๐Ÿ’‰
Image: Insert cartridge into pen space
Step 4

Insert the Converted Cartridge

Insert the cartridge with the orange screw adapter attached into the cartridge space of the pen โ€” rubber stopper end facing the pen body plunger.

5
๐Ÿ”ง
Image: Reattach pen body with spacer at bottom
Step 5

Reattach the Pen Body

With the orange spacer in place at the bottom around the plunger, screw the pen body back onto the cartridge holder clockwise until firmly connected. The pen is now fully converted.

6
๐Ÿชก
Image: Attach pen needle
Step 6

Attach a Pen Needle

Screw a fresh pen needle onto the cartridge holder end clockwise until secure. Remove both needle shields before use.

7
โœ…
Image: Prime pen and confirm flow
Step 7

Prime the Pen

Dial 2 units and press the button to prime. A small drop at the needle tip confirms the pen is ready and air has been expelled.

8
๐Ÿ’Š
Image: Dial dose and perform injection
Step 8

Dial Your Dose and Inject

Dial to your target dose, wipe the injection site with an alcohol swab, insert subcutaneously and press the button fully. Hold for 10 seconds before removing.

โš ๏ธ
Cartridge Replacement

When replacing the cartridge, unscrew the pen body, remove the used cartridge, unscrew the orange adapter from the old cartridge and attach it to the new SeraNova cartridge. Reinsert and reassemble following Steps 3โ€“5 above.

๐Ÿ”ถ
Keep Both Orange Adapter Pieces Safe

The two orange adapter pieces are reusable and must be retained for every cartridge change. Do not discard them โ€” they are required for every future cartridge installation.

๐Ÿชก After Each Injection โ€” Needle Disposal
1

Replace the outer needle shield and unscrew the needle anticlockwise to remove safely.

2

Dispose of used needle safely. Never reuse pen needles between injections.

3

Replace the pen cap and store the pen refrigerated between 2โ€“8ยฐC until next use.

Storage & Cartridge Care

๐ŸŒก๏ธ
Temperature
Store cartridges refrigerated at 2โ€“8ยฐC. Do not freeze. Remove from fridge 30 minutes before use.
๐ŸŒ‘
Light & Heat
Protect from direct sunlight and excessive heat at all times.
๐Ÿ“…
In-Use Cartridge
Once in use keep the pen refrigerated. Use within 60 days of first use.

Need Help With Your Dose?

Use the SeraNova Dosage Calculator to find your exact dose units and the Dosing Protocols page for your complete research protocol.

Research Use Only. This guide is for educational and research purposes only. SeraNova products are not intended to diagnose, treat, cure, or prevent any disease. Always follow safe handling procedures. SAHPRA disclaimer applies.